Skip to main content
CerebraTech AI
Internal test

Connect machines and sensors. Pull data from old equipment with no data port.

  • 100%Processed on your own site
  • 20yrs+Works with old machines even without a data port

If any of this sounds familiar

  • A 20-year-old machine has no data port — you don't know how it's running until it breaks
  • No data on which machine breaks down most often
  • Maintenance runs on a fixed schedule instead of the machine's actual condition
  • Machine operating data is scattered and never centralized

How the system works

  1. Survey the machine on-site

    We check what electrical or mechanical signal the machine already gives off that data can be pulled from — status lights, motor sound, or vibration.

  2. Attach add-on sensors

    External sensors that don't require modifying the machine itself, such as current clamps or magnetic vibration sensors.

  3. Turn it into readable data

    Data is sent via Modbus or MQTT into a central system, showing machine status in real time.

An M12 5-pin connector diagram linking a sensor to the on-site processing boxA cross-section of a 5-pin M12 connector with each pin numbered and the standard wire colours (brown, white, blue, black, grey), running from the existing sensor box on the left to the on-site processing box on the right across five conductors.Existing sensor12345M12 · 5-pin A-codedProcessing boxRaspberry Pi · Modbus

Technical specifications

Wireless protocol
Modbus RTU, MQTT
On-site processing unit
Raspberry Pi 5 + AI HAT

Hardware used

฿8,000–40,000 per point (see the hardware page for the full table)

See full specs and prices on the hardware page
Legacy integration

Connects to your existing MES

Data collected is sent into your existing MES via MQTT or API, combining it with production data you already have — no separate screen to check.

Frequently asked questions

What this system cannot do

  • A machine with no electrical or mechanical signal to detect at all can't be read — there needs to be at least one physical connection point.
  • We don't yet have accuracy figures measured from a real customer project, since this is still in internal testing — we'll update this once pilot data is available.
  • It doesn't control the machine directly — it only reads and reports data. Control still runs through your existing systems.

Want to know if your old machine can be connected?

This site uses very few cookies

We use only the cookies necessary to remember your language choice and save this consent preference (your chosen theme is remembered via browser local storage, not a cookie). Our analytics tool uses no cookies and collects no personal data.

Read the cookie policy